Navigation by alphabet

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Rabas and Taborek correlation, for heat transfer in banks of low fin tubes, Rackett equation (modified) for liquid density Radiation: Radiation shields, in radiation heat transfer, Radiation source analysis, Radiative heat transfer: Radiators, automotive, construction, Radiometers, application in gas radiation property measurement, Radiosity, Stephan's law for, Radiosity-irradiation formulations in radiative heat transfer, Rankine cycle in refrigeration, Rao, B K Raoult's law for partial pressure, Rating of heat exchangers, Rayleigh instability, in free convection, Rayleigh number Reay, D Reboilers: Reciprocal mode integrating sphere, for reflection and transmission measurements in radiation, Rectangles: Rectangular ducts: Rectangular enclosures, free convective heat transfer in: Rectangular fins, for plate fin exchangers Reduced pressure, correlations for pool boiling using, Reference temperature: Refinery processes, fouling in, Reflection, of thermal radiation, from solid surfaces: Reflectivity, of solid surfaces, Reflectometer, heated cavity, Reflux condensers, Refractories, density of, Refractory surfaces, Refrigerants: Refrigerant 11 (Trichlorofluoromethane): Refrigerant 12 (Dichlorodifluoromethane): Refrigerant 13 (Chlorotrifluoromethane): Refrigerant 21 (Dichlorofluoromethane): Refrigerant 22 (Chlorodifluoromethane): Refrigerant 116: Refrigerant plant, entropy generation in, Refrigeration, heat transfer in, Regenerators and thermal energy storage, Regimes of heat transfer, in ducts, single phase flow, Reidel method, for predicting enthalpy of vaporisation, Reinforcing rings, for expansion bellows, Relaminarization, of turbulent flow, Reichenberg method, for effect of pressure on gas viscosity, Relief system design for shell-and-tube heat exchangers with tube side failure, Removal of fouling deposits: Renewable fuels, properties of, Renotherm, heat transfer medium, Repair, of expansion bellows, Residence times, in dryers: Resistance network analysis, Resistance (thermal) due to fouling: Reversible (minimum) work, in Reynolds number, Reynolds stress models, for turbulence, Rheologically complex materials, properties of: Rheological properties of drag reducing agents Rheology, shear flow experiments used in, Rhine, J M, Ribatski, G, Riblets for drag reduction, Richardson number, Richie, J M, Ring cells, in free convection, RODbaffles, in tube bundles with longitudinal flow, Rod bundles: Rohsenow correlation, for nucleate boiling, Roll cells, in free convection, Roller expansion, of tubes into tube sheets, Rose, J W, Rossby number, Rotary dryer, Rotating drums, heat transfer to particle bed in, Rotating surface, in an annular duct Rotation, as device for heat transfer augmentation, Roughness, surface: Rough walled passages, radiative heat transfer down, Rubber (sponge) balls, in fouling mitigation, Ryznar index for water quality,

Index

HEDH
A B C D E F G H I J K L M N O P Q R
Rabas and Taborek correlation, for heat transfer in banks of low fin tubes, Rackett equation (modified) for liquid density Radiation: Radiation shields, in radiation heat transfer, Radiation source analysis, Radiative heat transfer: Radiators, automotive, construction, Radiometers, application in gas radiation property measurement, Radiosity, Stephan's law for, Radiosity-irradiation formulations in radiative heat transfer, Rankine cycle in refrigeration, Rao, B K Raoult's law for partial pressure, Rating of heat exchangers, Rayleigh instability, in free convection, Rayleigh number Reay, D Reboilers: Reciprocal mode integrating sphere, for reflection and transmission measurements in radiation, Rectangles: Rectangular ducts: Rectangular enclosures, free convective heat transfer in: Rectangular fins, for plate fin exchangers Reduced pressure, correlations for pool boiling using, Reference temperature: Refinery processes, fouling in, Reflection, of thermal radiation, from solid surfaces: Reflectivity, of solid surfaces, Reflectometer, heated cavity, Reflux condensers, Refractories, density of, Refractory surfaces, Refrigerants: Refrigerant 11 (Trichlorofluoromethane): Refrigerant 12 (Dichlorodifluoromethane): Refrigerant 13 (Chlorotrifluoromethane): Refrigerant 21 (Dichlorofluoromethane): Refrigerant 22 (Chlorodifluoromethane): Refrigerant 116: Refrigerant plant, entropy generation in, Refrigeration, heat transfer in, Regenerators and thermal energy storage, Regimes of heat transfer, in ducts, single phase flow, Reidel method, for predicting enthalpy of vaporisation, Reinforcing rings, for expansion bellows, Relaminarization, of turbulent flow, Reichenberg method, for effect of pressure on gas viscosity, Relief system design for shell-and-tube heat exchangers with tube side failure, Removal of fouling deposits: Renewable fuels, properties of, Renotherm, heat transfer medium, Repair, of expansion bellows, Residence times, in dryers: Resistance network analysis, Resistance (thermal) due to fouling: Reversible (minimum) work, in Reynolds number, Reynolds stress models, for turbulence, Rheologically complex materials, properties of: Rheological properties of drag reducing agents Rheology, shear flow experiments used in, Rhine, J M, Ribatski, G, Riblets for drag reduction, Richardson number, Richie, J M, Ring cells, in free convection, RODbaffles, in tube bundles with longitudinal flow, Rod bundles: Rohsenow correlation, for nucleate boiling, Roll cells, in free convection, Roller expansion, of tubes into tube sheets, Rose, J W, Rossby number, Rotary dryer, Rotating drums, heat transfer to particle bed in, Rotating surface, in an annular duct Rotation, as device for heat transfer augmentation, Roughness, surface: Rough walled passages, radiative heat transfer down, Rubber (sponge) balls, in fouling mitigation, Ryznar index for water quality,
S T U V W X Y Z

Types of Heat Exchangers and Their Applications

DOI 10.1615/hedhme.a.000238

3.1 INTRODUCTION TO HEAT EXCHANGER DESIGN
3.1.2 Types of heat exchangers and their applications

A. Selection of a basic type of heat exchanger

The most important decision underlying design of a piece of heat transfer equipment is the selection of the basic type of equipment to be specified and designed for a given application. It is incumbent upon the designer, at a very early stage in the design process, to survey the range of basic equipment types available and to select the one most applicable to his or her particular process. If a clear-cut decision cannot be made, it will probably prove economically desirable to proceed with at least first-stage design on each type of equipment that may reasonably serve.

A consideration that often enters into the selection of a basic type is the availability of comprehensive and accurate design methods for that equipment. Thus, shell-and-tube exchangers, for which a generally very good design procedure is available, are often selected for a service in preference to another type that may be intrinsically preferable in the application but which lacks a comparable design method in which the designer may place confidence. There is justification for this philosophy, but it can be bought at too high a price. Most heat exchanger types have good design methods available for most applicable services, though the best methods are often proprietary to the manufacturers or to members of cooperative research organizations.

B. Double-pipe heat exchangers

A typical double-pipe heat exchanger is shown in Figure 1. Essentially, it consists of one pipe placed concentrically inside another one of larger diameter, with appropriate end fittings on each pipe to guide the fluids from one section to the next. The inner pipe may have longitudinal fins welded, brazed, or soldered to it either internally or externally to increase the heat transfer area for the fluid with the lower heat transfer coefficient. The double-pipe sections can be connected in various series or parallel arrangements for either fluid to meet pressure drop limitations and MTD requirements. The major use of double-pipe exchangers is for sensible heating or cooling of the process fluid where small heat transfer areas (typically up to 50 m2) are required. They may also be used for small amounts of boiling or condensation on the process fluid side.

... You need a subscriptionOpen in a new tab. to view the full text of the article. If you already have the subscription, please login here