                Input Data and Recommended Practices
DOI 10.1615/hedhme.a.000251
3.3.5 Input data and recommended practices
J. Taborek
In this section we deal with three subjects:
- The basic set of input data as required for shell-side rating calculations, but also including those required for design of the overall exchanger, that is, including tube-side flow. These are presented in Table 1.
 - Detailed comments to the input data, to give guidance to the designer as to proper practices and standards.
 - Preliminary calculations of correlational parameters derived from the input data, as required for subsequent calculations.
 
Table 1 Input data required for rating of segmentally baffled shell-and-tube exchangers
| Item | Symbol | Units | Description | 
|---|---|---|---|
| Shell-side geometry data | |||
| Tube and tube layout | |||
| 1 | Ds | mm | Inside shell diameter | 
| 2 | Dt | mm | Tube outside diameter | 
| 3 | Ltw | mm | Tube wall thickness | 
| 4 | Dti | mm | Inside tube diameter | 
| 5 | λtw | W/m K | Tube wall material thermal conductivity | 
| 6 | Ltp | mm | Tube layout pitch | 
| 7 | θtp | deg | Tube layout characteristic angle | 
| Tube length (Refer to Figure 2) | |||
| 8 | Lto | mm | Overall nominal tube length | 
| 9 | Lti | mm | Baffled tube length | 
| 10 | Lta | mm | Effective tube length for heat transfer area | 
| Baffle geometry (Figure 7) | |||
| 11 | Bc | % | Baffle cut as percent of Ds | 
| 12 | Lbc | mm | Central baffle spacing | 
| 13a | Lbi | mm | Inlet baffle spacing (optional) | 
| 13b | Lbo | mm | Outlet baffle spacing (optional) | 
| Nozzle | |||
| 14 | CN | code | Shell-side nozzle, impingement protection, annular distributor | 
| Tube bundle geometry | |||
| 15 | Ntt | Total number of tubes or holes in tubesheet for U-tubes | |
| 16 | Ntp | Number of tube passes | |
| 17 | Nss | Number of sealing strips (pairs) | |
| 18 | CB | code | Tube bundle type (FX, UT, SRFH, PFH, PTFH) | 
| 19 | Ltb | mm | Tube OD (Dt)-to-baffle hole clearance (diametral), Figure 12 | 
| 20 | Lsb | mm | Inside shell-to-baffle clearance (diametral), Figure 13 | 
| 21 | Lbb | mm | Inside shell-to-tube bundle bypass clearance (diametral), Figure 14 | 
| Temperatures | |||
| 22 | Tsi | °C | Shell-side temperature inlet | 
| 23 | Tso | °C | Shell-side temperature outlet | 
| 24 | Tti | °C | Tube-side temperature inlet | 
| 25 | Tto | °C | Tube-side temperature outlet | 
| Shell-side process information | |||
| 26 | Ṁs | kg/s | Shell fluid mass flow rate | 
| At shell fluid mean temperature | |||
| 27 | ρs | kg/m3 | Density | 
| 28 | λs | W/m K | Thermal conductivity | 
| 29 | (cp)s | J/kg K | Specific heat | 
| 30 | ηs | cP = mPa/s | Dynamic viscosity (may require two values) | 
| 31 | Rf,o | mK/W | Shell-side fouling resistance (referred to shell-side surface) | 
| Tube-side process information | |||
| 32 | Ṁt | kg/s | Tube fluid mass flow rate | 
| At tube fluid mean temperature | |||
| 33 | ρt | kg/m3 | Density | 
| 34 | λt | W/m K | Thermal conductivity | 
| 35 | (cp)t | J/kg K | Specific heat | 
| 36 | ηt | cP = mPa/s | Dynamic viscosity (may require two values) | 
| 37 | Rf,i | m K/W | Tube-side fouling resistance (referred to inside tube surface) | 
| Special information | |||
| 38 | αs | W/m2 K | Shell-side heat transfer coefficient; if specified, omit items as shown in comments | 
| 39 | αt | W/m2 K | Tube-side heat transfer coefficient; if specified, omit items as shown in comments | 
| 40 | (Δps)max | kPa | Maximum permissible pressure drop, shell side | 
| 41 | (Δpt)max | kPa | Maximum permissible pressure drop, tube side | 
| 42 | (vt)max | m/s | Maximum permissible tube-side flow velocity (optional) | 
| 43 | (vt)min | m/s | Minimum acceptable tube-side flow velocity (optional) | 
A. Basic input data