Nomenclature and References (Sections 3.9.1-3.9.13)
3.9.14 Nomenclature and References (Sections 3.9.1–3.9.13)
Ralph L. Webb
Nomenclature
a | parting sheet thickness for plate-fin heat exchanger |
a | short side of a rectangular flow passage |
Ac | exchanger minimum free flow area |
Af | exchanger total fin area on one side |
Afr | exchanger total frontal area |
b | long side of a rectangular flow passage |
b | plate spacing (or rectangular fin height) |
cp | specific heat at constant pressure |
C | flow stream capacity rate (ṁ cp); Cc (cold fluid), Ch (hot fluid), Cmin (minimum), Cmax (maximum) |
d | diameter of pin fin |
Dh | hydraulic diameter of any internal passage (Dh = 4rh = 4Ac L /A) |
ew | wave amplitude of wavy or herringbone fin |
f | mean friction factor, defined on the basis of mean surface shear stress |
F | two-phase convection multiplier defined by Figure 307.4 |
Gc | flow stream mass velocity based on minimum flow area, ṁ cp /Ac |
Gfr | flow stream mass velocity based on flow frontal area, ṁ cp /Afr |
H | louver fin height (Figure 301.3) |
Kc | contraction loss coefficient for flow at heat exchanger entrance |
Ke | expansion loss coefficient for flow at heat exchanger exit |
L | total heat exchanger flow length; also, flow length of uninterrupted fin |
LL | louver length normal to air flow (Figure 301.3) |
Lp | louver pitch or half-wave pitch of wavy or herringbone fin. |
m | fin effectiveness parameter (2α /k δ)1/2 |
ṁA | exchanger total heat transfer area on one side |
ṁ | mass flow rate |
NTU | number of heat transfer units of an exchanger (= U A /Cmin) |
Nu | Nusselt number (α Dh /k) |
OSF | abbreviation for "offset-strip fin" |
pcr | critical pressure |
pf | fin pitch; center-to-center fin pitch (see Figure 298.1) |
pr | reduced pressure (p /pcr) |
pw | half-wave pitch of wavy or herringbone fin |
Δp | pressure drop |
P | fin length from root to center |
P | friction power expended per unit of surface heat transfer area (see Equation 302.2) |
Pr | Prandtl number (η cp /λ) |
q | heat transfer rate, W/m2 |
rh | hydraulic radius (Ac L /A) |
R | flow stream capacity rate ratio (= Cmin /Cmax) |
Rp | empirical "roughness factor" used in Cooper boiling correlation (Equation 307.8) |
ReDh | Reynolds number based on hydraulic diameter (Dh G /η) |
ReLp | Reynolds number based on louver pitch (Lp G /η) |
s | center-to-center spacing |
S | suppression factor for convective vaporization |
St | Stanton number (α /G cp) |
T | temperature to any arbitrary scale |
Tp | transverse tube pitch of a flat-tube heat exchanger (Figure 301.3) |
U | unit overall thermal conductance |
u | velocity |
V | volume |
x | axial coordinate in flow direction |
Xtt | Martinelli parameter defined by Equation 307.6 |
Greek Symbols | |
---|---|
α | convection heat transfer coefficient |
αlo | convection heat transfer coefficient for all-liquid flow |
β | ratio of total heat transfer area on one side of a plate-fin heat exchanger to the volume between the plates on that side |
γ | ratio of total transfer area on one side of the exchanger to total volume for the exchanger |
δ | fin thickness |
Δ | denotes difference |
ε | heat exchanger thermal effectiveness, dimensionless |
η | dynamic viscosity |
ηf | fin efficiency, dimensionless |
ηs | fin surface efficiency, dimensionless |
θ | louver angle of louver fin (Figure 301.3) |
λ | thermal conductivity |
ρ | density |
σ | ratio of free-flow area to frontal area, Ac /Afr, dimensionless |
τo | unit surface shear stress |
(ϕlo)2 | friction multiplier [see Equation 307.12] |
Subscripts | |
c | cold side fluid |
cv | convective contribution in convective vaporization; nucleate boiling contribution in convective vaporization |
fd | fully developed condition |
g | gas phase |
h | hot side fluid |
l | liquid phase |
m | mean conditions, defined as used |
1 | indicate fluid 1 of a two-fluid heat exchanger |
2 | indicate fluid 2 of a two-fluid heat exchanger |
i | inlet condition |
o | outlet condition |
max | maximum |
min | minimum |